Planning an investigation
A good plan states clearly:
- the independent variable (what you change) and its range,
- the dependent variable (what you measure) and how,
- the control variables (what you keep the same, and how),
- the apparatus, with its size and resolution,
- the method in enough detail to repeat, including how many repeats,
- how the results will be processed, and
- the main hazards and how the risk is reduced.
To improve validity, control the other variables and measure what you intend to measure. To improve reliability, repeat and check that the repeats agree.
Measurements and uncertainty
- Resolution is the smallest division the instrument shows.
- Accuracy is how close a result is to the true value. Precision is how close repeated results are to each other.
- Random errors make readings scatter either side of the true value; repeating and averaging reduces them. Systematic errors shift all readings the same way (for example a zero error), and repeating does not remove them.
- A mean should use only concordant results.
The percentage uncertainty in a measurement is .
To reduce the percentage uncertainty: use a larger quantity (a larger titre or mass), or apparatus with a smaller uncertainty (a balance with more decimal places).
Presenting data
- Give a table with headings that have quantities and units.
- Record all raw data to the same number of decimal places, matching the instrument.
- Quote calculated results to the same number of significant figures as the least precise data.
Graphs
- Put the independent variable on the horizontal axis. Use a scale that fills more than half of the grid, with sensible steps, and label axes with quantity and units.
- Mark points with small crosses and draw a best-fit line (a smooth curve or a straight line with points either side). Do not force it through the origin unless the data show it should be there.
- The gradient of a line is found from a large triangle. For a curve, draw a tangent to give the rate at a point.
- Anomalous results are circled and can be left out of the line of best fit, but you should repeat them if possible.
Evaluating
For each source of error, say whether it is random or systematic, estimate its effect and suggest an improvement (more repeats, a bigger quantity, a more precise instrument, better insulation). Draw a conclusion that the data support, and say how confident you are. Compare the percentage uncertainty with the difference between results to judge whether the difference is significant.
Apparatus
Choose by the size and resolution needed: a measuring cylinder (±0.5 cm for 25 cm) for rough volumes, a pipette (25.0 cm, one fixed volume, low uncertainty) and burette (readable to ±0.05 cm) for titrations, a volumetric flask for standard solutions, a balance (0.001 g) for accurate masses, and a gas syringe for collecting gases. Know the apparatus for reflux, distillation, filtration under reduced pressure, and a thermometer or data logger.
Safety
Identify the hazard (corrosive, toxic, flammable, oxidising, irritant) from its symbol, name the risk and give the control: eye protection, gloves, a fume cupboard for toxic or irritant vapours, no naked flames near flammable liquids, dilute solutions, small amounts, and safe disposal.
The core practicals at a glance
| No. | Practical | Key idea |
|---|---|---|
| 1 | Molar volume of a gas | from mass of a solid reactant and gas collected |
| 2 | Enthalpy change with Hess's law | Temperature changes in cups, combine two cycles |
| 3 | Concentration of HCl | Titration against a standard base |
| 4 | Standard solution from a solid acid | Weigh by difference; volumetric flask |
| 5 | Rates of hydrolysis of halogenoalkanes | Time to precipitate with |
| 6 | Chlorination of 2-methylpropan-2-ol | Separating funnel, wash, dry, distil |
| 7 | Oxidation of propan-1-ol | Distillation versus reflux |
| 8 | Inorganic and organic unknowns | Test-tube tests with spectra |
| 9a, 9b | Iodine-propanone rate; iodine clock | Order of reaction |
| 10 | Activation energy | Rate against temperature, Arrhenius plot |
| 11 | of a weak acid | pH of a half-neutralised solution |
| 12 | Electrochemical cells | Measuring cell potentials |
| 13a, 13b | Redox titrations | Iron(II) with manganate(VII); thiosulfate with iodine |
| 14 | Transition metal complex | Preparation and purification |
| 15 | Unknowns | As core practical 8 |
| 16 | Aspirin | Preparation and recrystallisation |