NMR spectroscopy, accurate mass and chromatography

High resolution mass spectrometry, carbon-13 and proton NMR including chemical shift, peak area and splitting, and paper, thin-layer, gas and high-performance liquid chromatography.

6 min read

Download this chapter (PDF)

High-resolution mass spectrometry

A high-resolution mass spectrometer measures m/zm/z to several decimal places. Because atomic masses are not whole numbers, different molecular formulae with the same nominal mass have different accurate masses, so the molecular formula can be identified.

Accurate relative atomic masses used: 1H=1.0078^{1}H = 1.0078, 12C=12.0000^{12}C = 12.0000, 14N=14.0031^{14}N = 14.0031, 16O=15.9949^{16}O = 15.9949.

The measured value is closest to 28.0062, so it is N2N_2.

To calculate an accurate mass, add the accurate masses of each atom in the formula, using four decimal places.

Carbon-13 NMR

Nuclear magnetic resonance spectroscopy uses radio waves to detect the behaviour of nuclei with spin in a magnetic field. 13C^{13}C NMR gives information about carbon environments.

  • One peak per distinct carbon environment. Carbons that are in an identical environment by symmetry give a single peak.
  • The chemical shift, δ\delta (in ppm, relative to tetramethylsilane, TMS, at 0), shows the kind of carbon.
Carbon environmentδ\delta / ppm
C–C (alkyl)5–40
C–Cl, C–Br25–80
C–O (alcohols, ethers)50–90
C=C (alkene) and aromatic100–150
C=O (carboxylic acid, ester)160–185
C=O (aldehyde, ketone)190–220

The number of peaks shows the number of different carbons. Propane has two peaks (the two CH3CH_3 carbons are equivalent), but propan-1-ol has three.

Proton NMR

Proton NMR gives information about the hydrogen atoms in a molecule. Samples are dissolved in a solvent without hydrogen (such as CDCl3CDCl_3 or CCl4CCl_4), with TMS as the reference.

What a spectrum shows

  1. Number of peaks – number of different proton environments.
  2. Chemical shift, δ\delta – the type of environment.
  3. Relative peak area (integration, often shown as a number or a trace) – the ratio of the numbers of protons in each environment.
  4. Splitting pattern (high resolution) – the number of protons on adjacent carbon atoms.
Proton environmentδ\delta / ppm
R−CH3R-CH_3, R−CH2−RR-CH_2-R0.9–1.7
CH3−C=OCH_3-C=O or CH2−C=OCH_2-C=O2.0–2.9
CH2−HalCH_2-Hal3.0–4.2
CH2−OCH_2-O (alcohols, esters)3.3–4.3
O–H (alcohols)1.0–5.5 (variable)
C=C–H4.5–6.0
Aromatic H6.0–9.0
Aldehyde, −CHO-CHO9.4–10.0
Carboxylic acid, −COOH-COOH10–12

The (n+1)(n+1) rule

A proton or group of equivalent protons with nn protons on the adjacent carbon(s) gives a peak split into n+1n + 1 lines.

Adjacent protonsSplittingNameRelative intensities
01Singlet1
12Doublet1 : 1
23Triplet1 : 2 : 1
34Quartet1 : 3 : 3 : 1

Equivalent protons on the same carbon do not split each other. Protons on −OH-OH typically show as a singlet because of exchange.

Three environments in the ratio 3 : 2 : 3. CH3CO−CH_3CO-: singlet at about δ\delta 2.0 (no adjacent H). −OCH2−-OCH_2-: quartet at about δ\delta 4.1 (3 adjacent H on the CH3CH_3). −CH3-CH_3: triplet at about δ\delta 1.3 (2 adjacent H).

Deuterium exchange: shaking with D2OD_2O makes the O–H or N–H peak disappear, which identifies it.

Chromatography

Chromatography separates the components of a mixture using a mobile phase and a stationary phase. Components differ in how strongly they are adsorbed on the stationary phase and how soluble they are in the mobile phase.

Paper and thin-layer chromatography (TLC)

  • Paper: the stationary phase is water held in the paper. TLC: a thin layer of silica or alumina on a plate.
  • Spot the sample on a pencil baseline, place in a covered container with the solvent below the line, let the solvent rise, and mark the solvent front. Spots may need a locating agent (UV light or ninhydrin for amino acids).

Rf=distance moved by the spotdistance moved by the solvent frontR_f = \frac{\text{distance moved by the spot}}{\text{distance moved by the solvent front}}

RfR_f is always less than 1. Different RfR_f values arise from the different affinities of the components for each phase. Compare with known standards, using the same solvent and conditions.

Gas chromatography (GC) and HPLC

These are column chromatography methods. Components pass through a column and emerge at different retention times.

  • GC: the mobile phase is an inert gas and the stationary phase is a liquid on a solid support in a column. Suited to volatile substances.
  • HPLC (high-performance liquid chromatography): a liquid under high pressure through a column of fine particles.

Both can be linked to a mass spectrometer (GC-MS), which identifies each component as it leaves the column. Applications include forensics, drug testing in sport, and detecting pollutants.