24.1 Electrolysis
In electrolysis an electric current drives a non-spontaneous reaction. At the cathode (negative electrode) reduction occurs; at the anode (positive electrode) oxidation occurs.
Predicting the products
- Molten electrolytes: the cation is discharged at the cathode and the anion at the anode (molten gives Pb and ).
- Aqueous solutions: water can also be discharged. At the cathode the species with the more positive (less negative) is reduced: metals below hydrogen in the series (Cu, Ag) are deposited; for reactive metals (Na, K, Ca, Mg, Al) hydrogen is released instead: . At the anode halide ions are oxidised in preference to water if concentrated (chlorine from concentrated NaCl); otherwise oxygen forms: or .
- Concentration matters: dilute NaCl solution gives oxygen at the anode, concentrated gives chlorine.
- The electrode material also matters; a copper anode dissolves (), as in copper refining.
Quantitative electrolysis
where is charge in coulombs, is current in amps, is time in seconds, is the Faraday constant (96 500 C mol⁻¹), is the Avogadro constant and is the charge on the electron ( C). The amount of electrons is .
C. Moles of electrons . , so moles of Cu and mass g.
Determining experimentally: electrolyse for a measured time at a known current, find the mass of metal deposited at the cathode (the change in mass of a copper electrode), then calculate the amount of atoms deposited, the charge passed and .
Charge carriers and electrode polarity
Electrons carry charge through wires and electrodes; ions carry charge through an electrolyte. Cations move towards the cathode and anions towards the anode, but migration alone does not prove which species is discharged. In water, hydrogen- or hydroxide-containing species may compete with the dissolved salt ions, and electrode material can participate.
Oxidation always occurs at the anode and reduction at the cathode. The signs differ between an electrolytic cell, where an external supply drives the process, and a galvanic cell, which supplies electrical energy spontaneously. In electrolysis the cathode is negative; in a working galvanic cell it is positive. Identify the cell type before attaching signs.
Worked example: electrolysing aqueous copper sulfate with inert electrodes deposits copper at the cathode, , and produces oxygen at the anode from water. With copper electrodes, oxidation of the copper anode can instead replace the ions removed at the cathode. State the electrode material when predicting products. Standard potentials guide predictions, but concentrations and kinetic effects such as overpotential can alter practical discharge behaviour.
Electrolysis calculations in both directions
The calculation chain is current and time → charge → moles of electrons → moles of product. The coefficient of electrons in the half-equation is the conversion factor, not the ion's subscript in a formula. Assume 100% current efficiency unless the question states otherwise.
Worked example: deposit 2.70 g Al from molten electrolyte using 5.00 A. mol. Since , electrons required are 0.300 mol. Charge is C, giving s, or 96.5 min. For a gas, calculate its moles first, then apply the stated molar volume or .
For an experimental Faraday constant, weigh a clean dry electrode before and after electrolysis. If a divalent metal of molar mass gains mass , electron amount is , so . Wet electrodes overestimate deposited mass; lost deposit underestimates it. Measure current throughout if it varies, rather than assuming an initial reading remains constant. Obtain from only after calculating the measured .
Answer: Electron amount is 0.0100 mol, equal to silver amount because one electron deposits one silver atom. Mass is 1.08 g. The same charge would deposit half as many moles of a 2+ metal.
24.2 Standard electrode potentials, standard cell potentials and the Nernst equation
Standard electrode potential
The standard electrode (reduction) potential, , is the voltage of a half-cell, measured with a standard hydrogen electrode as the other half-cell, under standard conditions: 298 K, 1.00 mol dm⁻³ for solutions of ions, and 101 kPa for gases. The half-equation is written as a reduction.
The standard hydrogen electrode (SHE)
A platinum electrode coated with platinum black, in contact with gas at 101 kPa and a solution of at 1.00 mol dm⁻³, at 298 K: , with V by definition.
Measuring
- A metal in contact with its ions (for example ): the metal in a 1.00 mol dm⁻³ solution of its ions, connected through a salt bridge and a high-resistance voltmeter to the SHE.
- Ions of the same element in different oxidation states (for example ): an inert platinum electrode in a solution containing both ions at 1.00 mol dm⁻³.
- For a non-metal such as : a gas bubbled around a platinum electrode in a solution of the ions.
Standard cell potential
The more positive is the positive electrode (reduction), and electrons flow in the external circuit from the negative to the positive electrode. The more negative half-cell is oxidised.
| Half-equation | / V |
|---|---|
| −2.38 | |
| −0.76 | |
| −0.44 | |
| 0.00 | |
| +0.34 | |
| +0.54 | |
| +0.77 | |
| +1.07 | |
| +1.33 | |
| +1.36 | |
| +1.52 |
Using values
- For half-equations written as reductions, the strongest oxidising agents are the species on the left of the most positive equations; the strongest reducing agents are the species on the right of the most negative equations. Do not rely on the table's physical top/bottom order.
- A reaction is feasible if . To build the overall equation, reverse the half-equation with the lower (more negative) , balance the electrons and add. For : V.
- Feasibility predicts the thermodynamics, not the rate; a reaction may be slow, and conditions may not be standard.
Building a cell and an overall equation
A single electrode potential cannot be measured in isolation; measure the potential difference against a reference half-cell. The standard hydrogen electrode defines zero, so a negative value means a half-cell is less favourable for reduction relative to that reference. The high-resistance voltmeter draws negligible current, helping preserve the conditions being measured. A salt bridge completes the internal ionic circuit without directly mixing the two solutions.
Worked example: combine , +0.77 V, with , +0.54 V. Iron(III) is reduced and iodide is oxidised. Multiply the iron half-equation by two to cancel electrons:
V. Do not multiply an electrode potential when multiplying a half-equation: potential is an intensive quantity. In contrast, the electron count used later in must match the balanced overall equation.
Answer: , because its reduction potential is more positive under the stated standard conditions. Compare the species accepting electrons, not the metals/ions appearing on the product side.
The Nernst equation
When concentrations are not 1.00 mol dm⁻³ the electrode potential changes. At 298 K:
where is the number of electrons in the half-equation.
- For : . Diluting the solution makes less positive.
- For : .
Qualitatively, increasing the concentration of the oxidised species makes more positive, since the equilibrium moves towards the reduced form (the opposite for the reduced species).
V.
Applying Nernst with the correct ratio
The reduced form may be a pure solid, whose concentration is omitted. For a pair of aqueous ions, include both concentrations. A tenfold change in their ratio changes by V at 298 K. Use base-10 logarithms with the given 0.059 coefficient and do not substitute the number of electrons in an unrelated overall cell reaction for the half-equation's .
Worked example: for with and mol dm⁻³, V. The increased oxidised-to-reduced ratio makes reduction more favourable. If both concentrations are diluted by the same factor, their ratio is unchanged in this simple expression.
For equations containing several ions or gas-pressure terms, use the appropriately stated form of the equation; the simple single-ratio examples are not permission to ignore coefficients or additional species. Qualitative concentration reasoning and numerical substitution should agree about the direction of the potential change.
Answer: V. The negative logarithm reduces the potential.
and the cell potential
where is the number of moles of electrons transferred in the balanced equation and C mol⁻¹. A positive gives a negative (feasible). The result is in J mol⁻¹; divide by 1000 for kJ mol⁻¹.
and V, so J mol⁻¹, or −212 kJ mol⁻¹.
Interpreting feasibility and its limits
For the iron(III)/iodide example above, two moles of electrons are transferred, so kJ mol⁻¹ for the balanced reaction. Reversing the reaction changes the signs of both cell potential and free energy. Doubling the equation doubles and , but leaves the potential unchanged.
A positive cell potential predicts a thermodynamic driving force under the stated conditions. It does not specify the rate, the time needed for completion or the extent to which competing reactions occur. Non-standard concentrations, surface films and slow electron-transfer kinetics help explain why a predicted reaction may not be observed immediately.
Chapter check: identify cell type, label electron flow through the wire and ionic movement through the bridge, balance electrons, then use the appropriate potential expression. Link sign and feasibility reasoning to Gibbs free energy.
References and further reading
Scope follows section 24 of the Cambridge 9701 syllabus for 2025–2027. Chemguide’s Cambridge topic index links to alternative explanations. The worked exercises and added diagrams are original teaching examples; numerical examples are illustrative unless a specific source is identified.
Practise this chapter
Every past-paper question on these topics, with the mark scheme.
These notes are AI generated and may contain mistakes. Check them against your syllabus.