Note AcademyNote Academy

Physics · May / June 2022 · Paper 31 · Question 2

YPH11

As printed in the paper

The question as text

2 A student directed a ray of light from air into a semi‑circular block of transparent material as shown. incident ray semi-circular block θ1 θ2 refracted ray He varied the angle of incidence θ1 and measured the corresponding angles of refraction θ2. He used the protractor shown below. (Source: PAL)

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 2(a)[3]

    Uncertainty is half resolution (0.5˚)

    Use of percentage uncertainty = (uncertainty / angle value) × 100% for either

    angle

    % uncertainty in θ1 = 1.4% (accept 1%) and % uncertainty in θ2 = 0.8%

    If the full resolution of protractor is used (1˚) – award MP2 for use of equation and

    MP3 for correctly values 2.9% (3%) and 1.6% (2%)

    Example Calculation

    % uncertainty in θ1 = (0.5˚ / 35˚) × 100% = 1.4%

    % uncertainty in θ2 = (0.5˚ / 62˚) × 100% = 0.81%

  • 2(b)(i)[3]

    See n1 sinθ1 = n2 sin θ2 with refractive index of air n2 = 1

    Or rearranges and compares 𝑛𝑛1 =

    sin 𝜃𝜃1 with gradient =

    sin 𝜃𝜃2

    ∆sin 𝜃𝜃2

    Rearranges and compares with y = mx (+ c)

    ∆sin 𝜃𝜃1

    Identifies n1 = gradient

    𝑛𝑛2 =

    sin 𝜃𝜃1 with gradient =

    𝑛𝑛1

    sin 𝜃𝜃2

    ∆sin 𝜃𝜃2

    For MP1 accept n sinθ1 = sin θ2

    ∆sin 𝜃𝜃1

    For MP2 accept comparing

  • 2(b)(ii)[2]

    Uses two points on the line to determine the gradient

    n1 between 1.46 and 1.54

    MP2 dependent on MP1

    MP2 allow correct use of gradient = 1/n from 2(b)(i)

    Example Calculation

    n1 = (0.77 – 0.17) / (0.50 – 0.10)

    n1 = 1.5

  • 2(c)[2]

    Realistic cause of a systematic error in measured data suggested

    Suitable method to reduce effect of the cause suggested

    MP2 dependent on MP1

    Examples

    Normal line not correctly drawn at 90˚ to the flat surface

    Use a protractor/set square to check the normal line

    Zero error because protractor not aligned correctly

    Ensure the protractor is aligned to the normal

    Ray of light not directed to centre of the flat surface

    Or incident ray not perpendicular to curved surface

    Mark the position of the centre of the flat surface on paper

    Block moved

    Mark the position of the block on paper

    Or tape the block in position

    Did not repeat measurements with angles of incidence either side of the normal

    Repeat measurements (for angles of incidence on both sides of the normal) and

    calculate mean value

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.