Physics · May / June 2022 · Paper 31 · Question 2
YPH11
As printed in the paper
The question as text
2 A student directed a ray of light from air into a semi‑circular block of transparent material as shown. incident ray semi-circular block θ1 θ2 refracted ray He varied the angle of incidence θ1 and measured the corresponding angles of refraction θ2. He used the protractor shown below. (Source: PAL)
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
2(a)[3]
Uncertainty is half resolution (0.5˚)
Use of percentage uncertainty = (uncertainty / angle value) × 100% for either
angle
% uncertainty in θ1 = 1.4% (accept 1%) and % uncertainty in θ2 = 0.8%
If the full resolution of protractor is used (1˚) – award MP2 for use of equation and
MP3 for correctly values 2.9% (3%) and 1.6% (2%)
Example Calculation
% uncertainty in θ1 = (0.5˚ / 35˚) × 100% = 1.4%
% uncertainty in θ2 = (0.5˚ / 62˚) × 100% = 0.81%
2(b)(i)[3]
See n1 sinθ1 = n2 sin θ2 with refractive index of air n2 = 1
Or rearranges and compares 𝑛𝑛1 =
sin 𝜃𝜃1 with gradient =
sin 𝜃𝜃2
∆sin 𝜃𝜃2
Rearranges and compares with y = mx (+ c)
∆sin 𝜃𝜃1
Identifies n1 = gradient
𝑛𝑛2 =
sin 𝜃𝜃1 with gradient =
𝑛𝑛1
sin 𝜃𝜃2
∆sin 𝜃𝜃2
For MP1 accept n sinθ1 = sin θ2
∆sin 𝜃𝜃1
For MP2 accept comparing
2(b)(ii)[2]
Uses two points on the line to determine the gradient
n1 between 1.46 and 1.54
MP2 dependent on MP1
MP2 allow correct use of gradient = 1/n from 2(b)(i)
Example Calculation
n1 = (0.77 – 0.17) / (0.50 – 0.10)
n1 = 1.5
2(c)[2]
Realistic cause of a systematic error in measured data suggested
Suitable method to reduce effect of the cause suggested
MP2 dependent on MP1
Examples
Normal line not correctly drawn at 90˚ to the flat surface
Use a protractor/set square to check the normal line
Zero error because protractor not aligned correctly
Ensure the protractor is aligned to the normal
Ray of light not directed to centre of the flat surface
Or incident ray not perpendicular to curved surface
Mark the position of the centre of the flat surface on paper
Block moved
Mark the position of the block on paper
Or tape the block in position
Did not repeat measurements with angles of incidence either side of the normal
Repeat measurements (for angles of incidence on both sides of the normal) and
calculate mean value
Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.