Note AcademyNote Academy

Physics · May / June 2021 · Paper 31 · Question 3

YPH11

As printed in the paper

The question as text

3 A student determined the viscosity of a liquid. The student measured the force required to pull a small sphere upwards through the liquid at a constant speed. thin thread connected to force meter measuring cylinder containing liquid rubber bands sphere

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 3(a)[3]

    Diameter value = 17.90 mm

    Use of half resolution (0.005 mm)

    Percentage uncertainty = 0.03 (%)

    Example of calculation

    Percentage uncertainty = (0.005 mm / 17.90 mm) × 100 % = 0.028 %

  • 3(b)[1]

    Check for zero error

    Allow do not overtighten

  • 3(c)(i)[3]

    When stationary, the reading on the force meter = weight (− upthrust)

    When moving (at a constant speed), the reading on the force meter = weight +

    drag (− upthrust)

    Subtracting the two readings gives the value of drag

    For MP1 and MP2 – accept descriptions given as an equation

    e.g. When stationary F1 = W – U

    When moving F2 = W + D − U

  • 3(c)(ii)[3]

    Subtracts the two forces (F = 0.09 N)

    Use of F = 6πηrv

    η = 1.7 (Pa s)

    Example of calculation

    F = 0.29 N – 0.20 N

    F = 0.09 N

    F = 6πηrv

    η = F/6πrv

    η = 0.09 N / (6 × π × 0.00895 m × 0.32 m s–1)

    η = 1.67 Pa s

  • 3(d)[4]

    A comment assessing uncertainty in force

    A comment assessing uncertainty in distance

    A comment assessing uncertainty in time

    Conclusion justified by their assessments

    MP4 requires some numerical comparison

    Examples of assessments for MP13

    Force

    Resolution of the force meter is 0.01 N, so percentage uncertainty is 11% (accept

    5.5% or 6%)

    Force difficult to keep constant, variation likely to be larger than 0.01 N

    Distance

    Meter rule resolution of 1mm, so percentage uncertainty is small

    Percentage uncertainty in distance measurement is 0.2% (accept 0.4%)

    Time

    Resolution of the stopwatch is 0.01 s, so percentage uncertainty is 0.6 % (accept

    1.2%)

    Time is short, so reaction time (0.2 s) will be a significant percentage (25%) or

    fraction (1/4) of the time measured

    Not enough time to move eyeline, so there may be parallax error when judging

    when the sphere has passed the rubber band.

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.