Chemistry (AS & A Level) · May / June 2026 · Paper 52 · Question 2
9701
As printed in the paper
The question as text
This question is about the rate of the reaction between aqueous sodium ethanedioate, Na2C2O4(aq), and aqueous sodium peroxydisulfate, Na2S2O8(aq). Na2C2O4(aq) + Na2S2O8(aq) 2Na2SO4(aq) + 2CO2(g) When Na2C2O4(aq) is in excess, the rate equation for this reaction is: rate = [Na2S2O8]m where is the rate constant and m is the order of the reaction with respect to Na2S2O8(aq). In an experiment, excess Na2C2O4(aq) is added to a sample of Na2S2O8(aq) in a side-arm conical flask. The volume of carbon dioxide gas, CO2(g), produced is measured at regular time intervals. Figure 2.1 shows the results from the experiment plotted on the grid. A curved line of best fit has been drawn. 0 0 2 4 6 8 10 12 200 400 600 800 time / s volume of CO2(g) produced / cm3 1000 1200 1400 1600 Figure 2.1
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
2(a)[2]
M1 labelled gas syringe M2 sealed apparatus using a bung / cork / stopper 2 M1 gas syringe must be attached (directly to) side arm R M1if delivery to gas syringe goes through extra apparatus eg condenser etc A ‘syringe’ / ‘glass syringe’ as label A for displacement of non-aqueous named liquid (instead of water) into an inverted labelled measuring cylinder A for any apparatus that is sealed and is capable of collecting a measured volume of gas e.g. displacement of water using a measuring cylinder e.g. gas syringe coming from hole in bung and side arm sealed A ‘lid’ as label for a clearly drawn bung. A ‘bung’ as label for what looks like a lid R lid as a label if it looks like a lid R if ‘sealed’ apparatus includes addition of solution that would push air into the gas syringe e.g. burette delivering a solution through the bung. I attempts at mixing solutions within sealed apparatus e.g. test-tube dangling on a string I lines across delivery tubes A for loose diagrams - if it looks like a bung at the top of the flask assume it to be sealed A non-tight connection of delivery tubes to side arm A loose piston in the gas syringe R sealed apparatus that would pop apart due to increased pressure Guidance If M2 (or M1) is given for a displacement of water apparatus be lenient with position of delivery tube at the bottom of the measuring cylinder. But it should not ‘enter’ the measuring cylinder above the water line or go through the wall of the water trough R M1 and M2 if a syringe being used to deliver reactants
2(b)[1]
time 1 I units R ‘time intervals’
2(c)[1]
the volume (of CO2) was measured / recorded too early / before 1000 s 1 A (recorded) time is greater than actual time for actual time A true time / real time for recorded time A time read / the time (seen) in the results table A reading was taken / recorded / measured at (880 – 920) s / (120 – 80) s early R timer was started / stopped too early / late I comments on volume error assume ‘the time was recorded’ means ‘the recorded time’ i.e. ‘time was recorded too late’ is correct i.e. ‘time was recorded too early’ is incorrect
2(d)[1]
a smooth curve that:
starts at the originis to the left of the original curveflattens at 10 cm3 and before 1300 sends at 1600 s 1 I points drawn on curve A curve to start within first four small squares of y-axis and at 0 on the x-axis R curves which cross original graph R curves which clearly stray outside y-axis A curves to stray up to a ¼ of a square above 10 cm3 as a ‘hump AND return to 10 cm3 R curves (with humps) that go too high above 10 cm3 R curves where horizontal part stops before 1400 s2(e)(i)[2]
[Na2S2O8] / mol dm−3 rate / mol dm−3 s−1 log [Na2S2O8] log (rate) 1.00 x 10–2 0.02760 –2.00 –1.56 5.74 x 10–3 0.01160 –2.24 –1.94 3.67 x 10–3 0.00549 –2.44 –2.26 2.88 x 10–3 0.00398 –2.54 –2.40 2.08 x 10–3 0.00250 –2.68 –2.60 1.57 x 10–3 0.00169 –2.80 –2.77 ✓ ✓ M1 column 3 M2 column 4 2 all values must be to 2 DP A ecf for M2 if all –ve signs are missing in both columns A ecf for -1.93 in column 4 if –2.43 is seen in column 3 A ecf for both –2.4 AND –2.6 seen in column 4 if –2.(0) AND –2.8 is seen in column 3
2(e)(ii)[2]
M1 all 6 points correctly plotted M2 line of best fit correctly drawn 2 If a point should be on a line, it must be on a line. If a point should not be on a line, it must not be on a line. If not supposed to be on the line, points must be within half a small square of the correct position and in the correct small square. Blobs/thick crosses should be less than ½ a square across and be correctly centred. A ecf for acceptable line of best fit for incorrectly plotted points I remnants of lines that have been rubbed out place tick for M1 on graph place tick for M2 to the left-hand side of graph Indicate any incorrect plots with colour tool once line of best fit must cover all the points line of best fit guidance:
line should meet right-hand side of grid above –1.6point at (–2.24, –1.94) should not be significantly above the line.2(e)(iii)[2]
2(e)(iv)[1]
correct values of y, m and x for use in y = mx + c where y and x are coordinates of a point of the line m is gradient calculated in 2 (e) (iii) AND determination of log k AND determination of k 1 A ecf of incorrect x and y values from co-ordinates in 2 (e) (iii) E.g. –1.94 = [2 (e) (iii) × –2.24] + log k Log k = –1.94 – [2 (e) (iii) × –2.24] k = 10–1.94 – [2 (e) (iii) x –2.24] A 1.55 to be used in place of 2 (e) (iii) A gradient from 2 (e) (iii) expressed as a fraction or calculator value A correct answer to 2 or more SF I RE after 2nd SF
2(e)(v)[1]
Method 1: [2 (e) (iii) – 1.5] × 100 OR [1.5 – 2 (e) (iii)] = Q% 1.5 1.5 AND (if Q% less than 4.5) AND (measurement) error OR (if Q% greater than 4.5) AND other factors Method 2: 4.5 % of 1.5 = 0.0675 AND 1.5 + 0.0675 = 1.5675 AND / OR 1.5 – 0.0675 = 1.4325 AND
2(e)(vi)[1]
it is reliable AND no anomalous results/points OR it is not reliable AND there is an anomalous point 1 The answer must match the graph A ‘(all) the points are on or (very) near to line (of best fit)’ A ‘outliers’ for ‘anomalous points’ A ‘(straight) line passing through / touching all points’ but I ‘straight line passing all points’ I ‘line fits the data’ A there is (only) one anomalous point, which must be identified, which can be ignored (and all the other points are on (or very near) line of best fit) I most of the points are on the line of best fit Not reliable lines of best fit will come from incorrect data plotting causing an anomalous point. Points near but not on the line are not anomalous unless the candidate has indicated this by a circle etc or by identifying the point using co-ordinates.