Chemistry (AS & A Level) · May / June 2025 · Paper 52 · Question 1
9701
As printed in the paper
The question as text
Activated carbon is a form of carbon with the ability to adsorb solutes from solutions. The adsorption of ethanedioic acid molecules, (COOH)2, from dilute ethanedioic acid, (COOH)2(aq), onto the surface of activated carbon is studied in a series of experiments. Before beginning the experiment, 500.0 cm3 of 0.139 mol dm–3 (COOH)2(aq), solution X, is made. The activated carbon is placed in an oven at 120 tC for three hours. The experimental procedure involves the following steps. step 1 Prepare 100.0 cm3 of 0.00556 mol dm–3 (COOH)2(aq) from solution X. step 2 Transfer 50.0 cm3 of the 0.00556 mol dm–3 (COOH)2(aq) into a conical flask. step 3 Add 0.500 g of activated carbon to the conical flask and start a stopwatch. step 4 Shake the flask and immediately remove a 5.0 cm3 sample from the flask. Determine the mass of non-adsorbed (COOH)2 in the sample using chromatography. step 5 Repeat step 4 at suitable time intervals until there is no further change in the mass of non-adsorbed (COOH)2 in the sample.
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
1(a)(i)[1]
8.76 (g)
1(a)(ii)[3]
M1 dissolve the solid / ethanedioic acid (in the beaker) using (a small volume of) (distilled) water M2 transfer / add to a (500 cm3 volumetric) flask AND rinse (with distilled water) M3 top the 500 cm3 volumetric flask up to mark (with distilled water) AND (stopper and) invert the flask
1(b)[1]
wear chemically resistant gloves
1(c)[1]
to remove water from (the surface of) the activated carbon
1(d)[1]
4.0 (cm3)
1(e)[1]
burette
1(f)[1]
to ensure a uniformly mixed sample
1(g)(i)[1]
time / mins mass of non-adsorbed (COOH) 2 in 5.0 cm3 sample / mg mass of (COOH) 2 adsorbed by activated carbon in 5.0 cm3 sample / mg 2.50 0.00 1.90 0.60 1.52 0.98 1.43 1.07 0.99 1.51 0.88 1.62 0.81 1.69 120 0.80 1.70 150 0.80 1.70
1(g)(ii)[2]
M1 all points plotted correctly M2 smooth curved line of best fit passing close to all points except marked anomaly
1(g)(iii)[1]
time (of sample removal)
1(g)(iv)[1]
temperature
1(g)(v)[1]
anomalous point circled (at 30 mins) AND the actual time (of removing sample) was less than recorded time (30 minutes)
1(h)(i)[3]
1(h)(ii)[1]
q0 = 1 / gradient in (h) (i)
1(i)[1]
Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.