Note AcademyNote Academy

Physics · Oct / Nov 2021 · Paper 31 · Question 1

YPH11

As printed in the paper

The question as text

1 A student investigated the behaviour of a thermistor using the circuit shown in the diagram. 12 V 4.7 kΩ V She heated the thermistor to 100 °C and measured the potential difference V across it. She decreased the temperature θ and recorded further measurements of V and θ until the temperature reached 10 °C.

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 1(a)[2]

    Heating (to 100 ˚C) – suitable method described

    (e.g. water bath, kettle)

    Cooling (to 10 ˚C) – suitable method described

    (e.g. ice bath, freezer)

  • 1(b)[2]

    Use of uncertainty = half resolution (0.005 V)

    Percentage uncertainty = 0.07 (%)

    Accept use of resolution (0.01 V), giving percentage uncertainty of

    0.15% for MP2 only

    Example calculation

    Percentage uncertainty = (0.005/6.85) × 100%

    Percentage uncertainty = 0.073%

  • 1(c)(i)[2]

    Line of best fit drawn up to V axis

    Value between 8.2 and 8.6 (V)

    MP1 – accept a straight line of best fit covering at least the first 5 plots

    MP2 – if a line of best fit is drawn, the value given must match the yaxis

    intercept ± 1 mm and be within the range stated

  • 1(c)(ii)[3]

    Use of 12 V = ∑ p.d.

    Use of V = IR

    Correct value calculated with unit

    Note – ecf from 1(c)(i) applies

    MP1 & 2 can be awarded for correct use of the potential divider ratios

    rule

    (e.g., Vfixed res / 12 V = 4700 Ω / (4700 Ω + Rtherm)

    Example calculation

    Vtherm = 8.4 V

    Vfixed = 3.6 V

    V = IR

    3.6 V = I × 4.7×103 Ω

    I = 3.6 V / 4.7×103 Ω = 7.7×10–4 A

    V = IR

    8.4 V = 7.7×10–4 A × R

    R = 8.4 V / 7.7×10–4 A = 1.1×104 Ω

  • 1(d)[2]

    Calculates V × θ for at least two pairs of values from the graph/table

    Or calculates proportional change for at least two pairs of values

    Conclusion consistent with values calculated

    Do not award MP2 if temperatures are not converted to Kelvin

    Example calculation

    Pair 1 V × θ = 3.5 V × (60 + 273 K) = 1170 V K

    Pair 2 V × θ = 5.7 V × (30 + 273 K) = 1730 V K

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.