Note AcademyNote Academy

Physics · May / June 2021 · Paper 51 · Question 19

YPH11

As printed in the paper

The question as text

19 A pacemaker is a device used to regulate a person’s heart rate. Some of the first electronic pacemakers used an isotope of plutonium, Pu-238, as the power source.

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 19(a)[5]

    Calculation of mass difference

    Conversion from u to kg, using a conversion factor of 1.66 ×10−27 kg u−1

    Use of ∆𝐸= 𝑐2∆𝑚

    Conversion of energy to eV

    ∆𝐸= 5.61 (MeV)

    Example of calculation

    Mass difference = 237.999089 u − 233.991578 u − 4.001506 u = 6.005 × 10−3 u

    Mass difference = 6.005 × 10−3 u × 1.66 ×10−27 kg = 9.9683 × 10−30 kg u−1

    ∆𝐸= 𝑐2∆𝑚= (3.00 × 108 m s1)2 × 9.9683 × 1030 kg = 8.9715 × 1013 J

    8.9715 × 10−13 J

    1.60 × 10−13 J MeV−1 = 5.607 MeV

    ∆𝐸=

  • 19(b)[5]

    Convert αparticle energy from MeV to J

    ln2

    Use of 𝜆=

    𝑡1/2

    Use of 𝐴= 𝐴0𝑒−𝜆 𝑡

    Use of 𝑃=

    ∆𝐸

    ∆𝑡

    P = 0.083 (W)

    Example of calculation

    5.6 MeV = 5.6 × 1.60 × 10−19 J MeV−1 = 8.96 × 10−13 J

    𝜆= ln2

    = 0.693

    87.7 year = 7.90 × 103 year1

    𝑡1/2

    6.75 × 1010 Bq = 𝐴0 e−7.90 × 10−3 year−1×40 year

    ∴𝐴0 = 9.26 × 1010 Bq

    𝑆𝑜 𝑃= 9.26 × 1010s1 ×8.96 × 1013 J = 0.0830 W

  • 19(c)[3]

    Maximum energy of beta particles read from graph 1

    (in range 210 keV → 225 keV)

    Beta particle range read from graph 2 (in range 0.05 cm → 0.08 cm)

    Or max. energy for 0.5 cm polyethylene read from graph.2

    (in range 1000 keV → 1200 keV)

    Conclusion that 0.5 cm polyethylene would be sufficient

    MP3 dependent on MP1 and MP2

    Pearson Education Limited. Registered company number 872828

    with its registered office at 80 Strand, London, WC2R 0RL, United Kingdom

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.