Note AcademyNote Academy

Chemistry · Oct / Nov 2021 · Paper 51 · Question 1

YCH11

As printed in the paper

The question as text

1 The apparatus shown was used to measure the standard electrode potential for the 2– ions to Cr 3+ ions in acid solution: reduction of Cr2O 7 Cr2O 7 2– (aq) + 14H+ (aq) + 6e– → 2Cr3+ (aq) + 7H2O(l) V H2 gas at salt bridge 100 kPa KNO3(aq) electrode 1 electrode 2 solution 1 solution 2

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 1(a)[1]

    The only correct answer is D (Pt, Pt)

    A

    is incorrect because both electrodes should be made of platinum

    B

    is incorrect because both electrodes should be made of platinum

    C

    is incorrect because both electrodes should be made of platinum

  • 1(b)[1]

    The only correct answer is C (1.00 mol dm−3 HCl(aq))

    A

    is incorrect because H3PO4 is not completely ionised

    B

    is incorrect because H2SO4 is not completely ionised

    D

    is incorrect because CH3COOH is not completely ionised

  • 1(c)[1]

    The only correct answer is B (17.91 g)

    A

    is incorrect because there should be only one mol of chromium ions per mol of dichromate ions

    C

    is incorrect because there should be only one mol of chromium ions per mol of dichromate ions

    D

    is incorrect because there should be only one mol of chromium ions per mol of dichromate ions

  • 1(d)[1]

    The only correct answer is A (H2SO4)

    B

    is incorrect because chloride ions could be oxidised

    C

    is incorrect because bromide ions would be oxidised

    D

    is incorrect because this would introduce additional chromium species into the mixture

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.