4 Students were set a challenge by their teacher to produce a chemical clock measuring a 20 s time interval. They used an opaque solution that became transparent, allowing a black cross to become visible after 20 s. white paper with large black ‘X’ The students investigated the effect of temperature on their results and plotted a graph. 50 45 40 35 30 Time t / s 25 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Temperature / °C

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 4(a)(i)[3]

    An answer that makes reference to the following points:

    calculation of rate

    Example of a calculation:

    Time read from graph = 33 seconds

    1 ÷ 33 = 0.0303

    Allow answer left as fraction

    answer to 1 or 2 SF

    0.030 / 0.03

    TE from M1 for values between 32.5 and 33.5

    units

    s‒1

    Allow “per second”

    Allow sec‒1 / seconds‒1

    Allow “/s”

    Marks are independent

  • 4(a)(ii)[1]

    line that shows rate increasing with temperature

    Example of a graph:

    AND

    line is curved with the gradient increasing

    Allow a graph starting from the origin

  • 4(b)[2]

    An explanation that makes reference to the following

    points:

    Allow all but one point follow a pattern

    all but one point is on the best fit line / there is

    Allow reference to point at 40° not being correct

    one anomaly (at 40°C) / a clear trend can be

    Allow outlier in place of anomaly

    seen

    Allow not necessary to repeat the experiment as

    it is not necessary to repeat the experiment as

    the pattern between rate and temperature

    the anomaly has been identified (and excluded

    is clear

    from the line of best fit)

    Allow not necessary to repeat as results are

    consistent

    Ignore comments about accuracy

  • 4(c)[1]

    An answer that makes reference to the following points:

    reduce the concentration (of one or more of the

    Allow specific suggestions

    reactants)

    e.g. doubling/increasing volume, use a

    thinner/paler cross, dilute the solution

    Allow amount for volume

    Ignore pressure

    Ignore suggestions related to maintaining

    temperature at 22°C

    Do not award “reduce the concentration of the

    opaque solution”

    Do not award “use a different type of opaque

    solution”

    (Total for Question 4 = 7 marks)