Chemistry · Oct / Nov 2021 · Paper 11 · Question 3
YCH11
As printed in the paper
The question as text
3 The diagram shows a mass spectrometer. + R S T to vacuum pump detector
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
3(a)[1]
The only correct answer is B (electrons are removed from molecules or atoms and positive ions are formed)
A is incorrect because the sample has been vaporised previously
C is incorrect because electrons are not added to atoms (in this mass spectrometer)
D is incorrect because acceleration occurs in region S
3(b)[1]
The only correct answer is A (ions with a greater mass have a smaller deflection)
B is incorrect because ions with a greater mass have a smaller deflection
C is incorrect because ions with a greater charge have a greater deflection
D is incorrect because ions are not speeded up in a magnetic field
Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.