Chemistry (AS & A Level) · May / June 2026 · Paper 54 · Question 1
9701
As printed in the paper
The question as text
A student uses two different methods to determine the value of integer x in hydrated sodium carbonate crystals, Na2CO3•xH2O(s). Method 1 The student uses the following procedure. step 1 Weigh an empty crucible. step 2 Add approximately 5 g of Na2CO3•xH2O(s) to the crucible. step 3 Weigh the crucible and contents. step 4 Heat the crucible and contents for 5 minutes. step 5 Allow the crucible to cool. Weigh the crucible and residue.
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
1(a)[1]
(re)heat and (re)weigh to constant mass 1 A “heat to constant mass” A description of the process of heating to constant mass A “crucible and residue” or “sample” for “crucible and contents” R “heat to constant weight”
1(b)(i)[1]
(mass of Na2CO3
xH2O(s) added / g =) 4.89 (mass of residue / g =) 2.06 AND (mass of water lost =) 2.83 1 R any other values.1(b)(ii)[1]
increase the mass of Na2CO3
xH2O(s) used 1 A use more (than 4.89 g / mass calculated in 1 (b) (i) of) Na2CO3xH2O(s) A use of “amount” for “mass” A use of “solid” or “crystals” or “contents” or “reactant” or “sample” or “hydrated sodium carbonate” or “sodium carbonate crystals” for “Na2CO3xH2O(s)” A increase the “mass of crucible and contents” I changes to heating I repeat and take mean R changing the crucible. e.g. increase the mass of crucible alone R “anhydrous sodium carbonate” / “sodium carbonate” alone / “powder” / Na2CO3 for “Na2CO3xH2O (s)” R incorrect use of “weight” for “mass” but A ecf from 1 (a). R heat to constant mass1(c)[2]
M1 n(H2O) = 2.83 / 18 = (0.157(222)) AND n(Na2CO3) = 2.06 / 106 = (0.0194(34)) M2 x = ( ) ( ) H2O Na2CO3 n n = (0.157 / 0.0194 = 8.09 → 8) 2 M1 A ecf from 1b(i) A rounding of amounts e.g. n(H2O) = 0.16 and n(Na2CO3) = 0.02 A valid alternative calculation routes A ecf from M1 if values used in M2 are calculated n(H2O) and n(Na2CO3). R non-integer value for x. e.g. 8.0
1(d)(i)[3]
M1 add a (small) volume of (distilled) water (to the small beaker) AND dissolve the solid / Na2CO3
xH2O(s) Transfer the solution and washings (using a funnel) AND into a 250 cm3 volumetric flask. 3 A ‘solution' produced in M1 or M2 for “dissolve the solid”. A “solid disappears” for dissolves. A extra transfers as long as the exact number of moles of solid end up in the volumetric flask via rinsing. (Allow greater volume added when accommodated by vessel used.) A prepare / make a solution for dissolve. I use of measuring cylinder / stirring / glass rod I description of measuring mass / incorrect mass used R water volume > 50 cm3 if specified OR fill (50 cm3) beaker A “rinse the beaker” or “wash the beaker” in place of “washings” BOD assume rinsing and washing is of the beaker into the flask if not clearly indicated otherwise e.g. to wash the apparatus A 250 volumetric flask / 250 cm3 graduated flask / 250 cm3 standard flask A M2 If solid added directly to 250 cm3 volumetric flask AND beaker (+ funnel) are rinsed, and washings added to flask AND the solid dissolved in distilled / deionised water in flask before M3 I use of funnel / glass rod I rinse the volumetric flask (with (distilled) water)(before adding solid / solution) R transfer solution with burette or pipette R weighing solid into flask Guidance ctd. M3 Make up to the (calibration) mark / line (with distilled water). AND then invert (the stoppered flask) (several times) A ‘250 cm3 calibration’, ‘line’ or other similar for ‘mark’. A deionised water, DW, dH2O, diH2O for ‘distilled water’. A make up to 250 cm3 (with distilled water). A ‘shake’, ‘swirl’ and ‘invert’ for ‘invert flask’. Must describe action, not ‘mix’ alone. A M2 and M3 if all correct except volume used to dissolve in M1 > 50 cm3 < 250 cm3 if specified. A use of pipette / burette to fill to mark. I top up / fill alone. I homogenise / mix R stir R M3 if solid not dissolved before making up to the mark. If purpose of inverting / shaking is to dissolve solid. A ecfM3 for volume > 250 cm3 (i.e. I volume from M1 and M2 when marking M3) Distilled / deionised water only needs to be mentioned once to infer its use throughout. If not mentioned, then M3 not awarded.
1(d)(ii)[1]
(0.01(00) mol dm–3) hydrochloric acid / HCl(aq)). 1 A (rinse with the) solution to be used (for the titration in the burette) A dilute hydrochloric acid I wash with distilled water / propanone before wash with (0.0100 mol dm-3) HCl R wash with distilled water / propanone after wash with (0.0100 mol dm-3) HCl
1(e)(i)[1]
(it is calculated from) titrations 1 and 3 AND which are concordant. 1 A titrations 1 and 3 (are used), which are within 0.1(0) (cm³) of each other / are ±0.1(0) (cm3) A the difference between titres 1 and 3 is 0.1(0) (cm³) A the difference between titres 1 and 3 is equal or less than 0.1(0) (cm³) A the difference between titres 1 and 3 is within 0.1(0) (cm³) (of each other) A values for titrations 1 and 3. e.g. 25.25 and 25.15 A values clearly indicated and annotated in Table 1.1 I mention of not using titration 2 R if titration 2 is used
1(e)(ii)[4]
M1 n(HCl) in mean titre= 0.0252 × 0.0100 = 2.52 × 10–4 (mol) M2 n(Na2CO3) in 25.0 cm3 of solution = (2.52 × 10-4 ÷ 2) = 1.26 × 10–4 (mol) M3 n(Na2CO3) in 250.0 cm3 of solution = 1.26 × 10–4 × 10 = 1.26 × 10–3 (mol) Mr (Na2CO3
xH2O) = 0.365 / 1.26 × 10–3 = 289.68 M4 x = (289.68 – 106) / 18 = 10.20 → 10 Missing factor of 10 in M3 leads to x = 155. M4 still available. Missing ÷ 2 in M2 leads to x = 2. M3 and M4 still available. 4 A ecf throughout A valid alternative calculation routes M3 A m(Na2CO3) in 0.365 g = 1.26 × 10–4 × 10 × 106 = 0.134 g m(H2O) = 0.365 – 0.134 = 0.231 g n(H2O) = 0.231 / 18 = 0.012858 M4 x= 0.012858 / 1.26 × 10–3 = 10.20 → 10 AECF for M4 if values used are calculated n(H2O) and n(Na2CO3). M4 R non-integer value for x, but A ecf from e.g. 8.0 in 1 (c) for e.g.10.0.
1(e)(iii)[1]
correct working must be shown maximum percentage error = 2 × 0.05 25.15 × 100 = 0.3976(14) 1 A 2 × (½ × 0.10) 25.15 × 100 = 0.3976 A 0.05 + 0.05 25.15 × 100 = 0.3976 A the following values for the answer following a correct expression – 0.4, 0.40, 0.39, 0.397 etc I missing × 100 if correct answer given R incorrectly calculated answer with correct working R (0.005 × 2 / 25.15) × 100 = 0.0398
1(f)[1]
(effect on value of =) increases AND n(Na2CO3) is lower OR n(H2O) is greater (than true value). OR (effect on value of x =) no / negligible effect AND value of x is to the nearest integer so (small) change in volume does not affect value 1 A ‘higher’ or ‘greater’ or ‘overestimated’ for ‘increases’ etc A “decreases” or “smaller” or “underestimated” for “lower” etc A ‘sodium carbonate’ or ‘Na2CO3
xH2O(s)’ for ‘Na2CO3’ A ‘number of moles’ or ‘mole number’ or ‘amount’ for n I powder / crystals I measured volume of solution A / Na2CO3 (aq) is less I recorded volume of solution A / Na2CO3 (aq) is larger A ‘slight increase’ for ‘negligible’
Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.