Benzenediazonium chloride, C6H5N2Cl , decomposes in water as shown in the following equation. C6H5N2Cl (aq) + H2O(l) C6H5OH(aq) + N2(g) + HCl (aq) A solution of 0.0750 mol dm–3 of C6H5N2Cl (aq) decomposes at a constant temperature of 50 °C. The volume of nitrogen gas, N2(g), collected is recorded every 5 minutes for 45 minutes.
Read automatically from the paper; the printed page above is exact.
Show the answer and mark scheme
2(a)[3]
M1: Leakproof reaction vessel capable of delivering a sample of gas. M2: Suitable method of collection and measurement of the gas produced. (eg. over water or gas syringe). M3: method for monitoring & maintaining temperature (thermostatically controlled water bath).
2(b)(i)[2]
M1: A tangent line which is…
a straight linestarts at / passes through 0,0.keeps to the left of the curve of the original line.covers at least 25 cm3 (5 big squares) on y-axis.passes between 4.0 and 5.5 minutes (inc.) at 25 cm3 M2: correct calculation of the gradient of tangent line drawn.2(b)(ii)[1]
The total volume of gas produced divided by the time taken is the mean rate (rather than the initial rate).
2(b)(iii)[1]
It (the line / curve) would be below / lower (than the one on the graph) (starting at 0,0).
2(b)(iv)[1]
A second curve which:
starts at 0,0 (± 1 small square)is less steep than curve for 0.0750 moldm-3. (before any plateau)produces 27.5 cm3 gas in total by 45 minutes. (± half a small square).Extends from 0 – 45 minutes.2(c)(i)[1]
concentration rate 0.5 0.000714 7.14 ×10-4 0.4 0.000455 4.55 ×10-4 0.3 0.000313 3.13 ×10-4 0.2 0.000234 2.34 ×10-4 0.1 0.000123 1.23 ×10-4
2(c)(ii)[1]
explanation using numbers from the table that whatever change is made to the concentration causes the same change in the rate (within experimental error).
2(c)(iii)[1]
time (taken to collect 0.0150dm3 of N2)
2(c)(iv)[3]
M1: Correct volume, 40(.0) cm3, (of 0.5(00) moldm-3) C6H5N2Cl(aq) is used / measured. M2: measure the volume from M1 C6H5N2Cl using a (50 cm3) burette into a 100 cm3 volumetric flask. M3: make up to the (calibration) mark with distilled water. AND then mix the solution (by inverting the flask)
2(c)(v)[1]
to make sure the concentration does not change (from 0.200 moldm-3) (by making sure the C6H5N2Cl does not decompose)
2(d)(i)[2]
Two acceptable reasons for low yield. Some C6H5N2Cl had decomposed / reacted with water (before reacting with phenylamine) OR temperature rose above 5 oC (in step 1) OR phenylamine used was impure. Some dye / solid is not recovered / is lost through / left in filter OR some of the dye dissolves in the water / is aqueous (in step 2).
2(d)(ii)[1]
(Residual) water causes solid to have a different / inaccurate (lower) melting point (to the dry solid). OR To ensure all water has been driven off to increase accuracy in measurement of melting point