Note AcademyNote Academy

Chemistry (AS & A Level) · Feb / March 2023 · Paper 52 · Question 2

9701

As printed in the paper

The question as text

The reaction between iodide ions, I–(aq), and aqueous hydrogen peroxide, H2O2(aq), takes place in acidic conditions. reaction 1 2I–(aq) + H2O2(aq) + 2H+(aq) I2(aq) + 2H2O(l) A student carries out a series of experiments to investigate the order of reaction with respect to the concentration of I–(aq) ions. The student does this by measuring the time taken for a fixed amount of iodine to form. A known amount of aqueous thiosulfate ions, S2O3 2–(aq), in the reaction mixture react with I2(aq) formed in reaction 1. reaction 2 I2(aq) + 2S2O3 2–(aq) 2I–(aq) + S4O6 2–(aq) After all of the S2O3 2–(aq) ions have reacted in reaction 2, any further I2(aq) formed is detected using starch indicator. The following materials are used: ● 50 cm3 beaker containing the correct mass of solid potassium iodide crystals needed to make 250.0 cm3 of 0.100 mol dm–3 KI(aq) ● 0.100 mol dm–3 Na2S2O3(aq) ● 0.100 mol dm–3 H2O2(aq) ● 0.200 mol dm–3 H2SO4(aq) ● starch indicator ● distilled water.

Read automatically from the paper; the printed page above is exact.

Show the answer and mark scheme
  • 2(a)[1]

    (not all) reactants may feature in the rate determining step OR order can only be determined experimentally

  • 2(b)[3]

    M1 Dissolve the solid / potassium iodide (in the beaker) (using a small volume of) (distilled) water M2 Transfer / add to a (250 cm3 volumetric) flask AND Rinse (with distilled water) M3 Top the 250 cm3 volumetric flask up to mark (with distilled water)

  • 2(c)(i)[1]

    Repeat the experiment to show the results are reproducible.

  • 2(c)(ii)[1]

    Volume of KI

  • 2(c)(iii)[1]

    Step 4

  • 2(d)(i)[2]

    Log V Log(1 / t) 0.699 –2.41 1.00 –2.08 1.10 –2.05 1.18 -1.88 X X 1.30 –1.75 1.40 –1.64 M1 Log V Correct values to 3 SF M2 log(1 / t) Correct values to 3 SF

  • 2(d)(ii)[2]

    M1 6 points plotted correctly M2 Line of best fit drawn

  • 2(d)(iii)[1]

    Point at log V = 1.10 and (recorded time is too high because) watch started too early or stopped too late

  • 2(d)(iv)[2]

    M1 Co-ordinates read and recorded correctly M2 Gradient calculated to 2 decimal places

  • 2(d)(v)[1]

    percentage error of experimental value = (2 (d) (iv) – 1.00) / 1.00] × 100 (assuming 2 (d) (iv) is 1.10) = [(1.10 – 1.00) / 1.00] × 100 = 10% (10% > maximum percentage error / 5.25%) AND other factors (beyond measurement caused the error)

Make a free account to save your answers and see your weak topics and ask the AI why a wrong answer is wrong.